sane-plustek(5) | SANE Scanner Access Now Easy | sane-plustek(5) |
NAME¶
sane-plustek - SANE backend for LM983[1/2/3] based USB flatbed scanners
DESCRIPTION¶
The sane-plustek library implements a SANE (Scanner Access Now Easy) backend that provides access to USB flatbed scanners based on National Semiconductor Merlin chipsets (LM9831, 9832 and 9833). If you're looking for parallel-port support for Plustek scanner please refer to the sane-plustek_pp(5) backend.
SUPPORTED DEVICES¶
The Backend is able to support USB scanner based on the National Semiconductor chipsets LM9831, LM9832 and LM9833. The following tables show various devices which are currently reported to work. If your Plustek scanner has another Product ID, then the device is NOT supported by this backend.
Vendor Plustek - ID: 0x07B3
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- OpticPro U12 LM9831 600x1200dpi 42bit 512Kb 0x0010 OpticPro UT12 LM9831 600x1200dpi 42bit 512Kb 0x0013 OpticPro UT12 LM9832 600x1200dpi 42bit 512Kb 0x0017 OpticPro UT16 LM9832 600x1200dpi 42bit 512Kb 0x0017 OpticPro U24 LM9831 1200x2400dpi 42bit 2Mb 0x0011 OpticPro U24 LM9832 1200x2400dpi 42bit 2Mb 0x0015 OpticPro UT24 LM9832 1200x2400dpi 42bit 2Mb 0x0017
Vendor KYE/Genius - ID: 0x0458
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2007 Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2008 Colorpage HR6A LM9832 600x1200dpi 42bit 512Kb 0x2009 Colorpage HR7 LM9832 600x1200dpi 42bit 512Kb 0x2013 Colorpage HR7LE LM9832 600x1200dpi 42bit 512Kb 0x2015 Colorpage HR6X LM9832 600x1200dpi 42bit 512Kb 0x2016
Vendor Hewlett-Packard - ID: 0x03F0
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- ScanJet 2100C LM9831 600x1200dpi 42bit 512Kb 0x0505 ScanJet 2200C LM9832 600x1200dpi 42bit 512Kb 0x0605
Vendor Mustek - ID: 0x0400
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- BearPaw 1200 LM9831 600x1200dpi 42bit 512Kb 0x1000 BearPaw 1200 LM9832 600x1200dpi 42bit 512Kb 0x1001* BearPaw 2400 LM9832 1200x2400dpi 42bit 2Mb 0x1001* see also description for model override switch below!
Vendor UMAX - ID: 0x1606
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- UMAX 3400 LM9832 600x1200dpi 42bit 512Kb 0x0050 UMAX 3400/3450 LM9832 600x1200dpi 42bit 512Kb 0x0060 UMAX 5400 LM9832 1200x2400dpi 42bit 512Kb 0x0160
Vendor COMPAQ - ID: 0x049F
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- S4-100 LM9832 600x1200dpi 42bit 512Kb 0x001A
Vendor Epson - ID: 0x04B8
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Perfection 1250 LM9832 1200x2400dpi 42bit 512Kb 0x010F Perfection 1260 LM9832 1200x2400dpi 42bit 512Kb 0x011D
Vendor CANON - ID: 0x04A9
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- CanoScan N650/656U LM9832 600x1200dpi 42bit 512Kb 0x2206 CanoScan N1220U LM9832 1200x2400dpi 42bit 512Kb 0x2207 CanoScan D660U LM9832 600x1200dpi 42bit 512Kb 0x2208 CanoScan N670/676U LM9833 600x1200dpi 48bit 512Kb 0x220D CanoScan N1240U LM9833 1200x2400dpi 48bit 512Kb 0x220E CanoScan LIDE20 LM9833 600x1200dpi 48bit 512Kb 0x220D CanoScan LIDE25 LM9833 1200x2400dpi 48bit 512Kb 0x2220 CanoScan LIDE30 LM9833 1200x2400dpi 48bit 512Kb 0x220E
Vendor Syscan - ID: 0x0A82
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Travelscan 662 LM9833 600x1200dpi 48bit 512Kb 0x6620 Travelscan 464 LM9833 600x1200dpi 48bit 512Kb 0x4600
Vendor Portable Peripheral Co., Ltd. - ID: 0x0A53
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Q-Scan USB001 LM9832 300x600dpi 42bit 512Kb 0x1000 Q-Scan USB201 LM9832 300x600dpi 42bit 512Kb 0x2000
Vendor Visioneer - ID: 0x04A7
---------------------------------------------------------- USB Model: ASIC: Properties: Prod-ID ---------------------------------------------------------- Strobe XP100 LM9833 600x1200dpi 48bit 512Kb 0x0427
OTHER PLUSTEK SCANNERS¶
For parallelport device support see the sane-plustek_pp(5)
backend.
The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner and is
supported by the sane-artec(5) backend.
Only the National Semiconductor LM983[1/2/] based devices of Plustek are
supported by this backend. Older versions of the U12, the UT12, the U1212
and U1248 (GrandTech chipset) are not supported.
Model Chipset backend ------------------------------------ U1248 GrandTech gt68xx UT16B GrandTech gt68xx OpticSlim 1200 GrandTech gt68xx OpticSlim 2400 GrandTech gt68xx U12 P98003 u12 UT12 P98003 u12 1212U P98003 u12For a more complete and up to date list see: http://www.sane-project.org/sane-supported-devices.html.
CONFIGURATION¶
To use your scanner with this backend, you need at least two entries in the configuration file /etc/sane.d/plustek.conf
[usb] vendor-id product-id
device /dev/usbscanner
[usb] tells the backend, that the following devicename
(here /dev/usbscanner) has to be interpreted as USB scanner device.
If vendor- and product-id has not been specified, the backend tries to
detect this by its own. If device is set to auto then the next
matching device is used.
The following options can be used for a default setup of your device. Most of
them are also available through the frontend.
The Options:
option warmup t
option lampOff t
option lOffonEnd b
option mov m
m/PID | 0x1000 | 0x1001 ------+--------------+--------------
0 | BearPaw 1200 | BearPaw 2400
1 | no function | BearPaw 1200
option invertNegatives b
1 --> invert picture
option cacheCalData b
1 --> save results of calibration in ~/.sane/ directory
option altCalibration b
1 --> use alternate calibration (only non Plustek devices, standard for CIS devices)
option skipFine b
1 --> skip fine calibration (only non Plustek devices)
option skipFineWhite b
1 --> skip white fine calibration (only non Plustek devices)
option skipDarkStrip b
1 --> always switch off the lamp for dark calibration, even a black strip is available
option skipCalibration b
1 --> skip calibration (only non Plustek devices)
option enableTPA b
1 --> override internal tables and allow TPA mode (EPSON/UMAX only)
option posOffX x
option posOffY y
option tpaOffX x
option tpaOffY y
option negOffX x
option negOffY y
option posShadingY p
option tpaShadingY p
option negShadingY p
option redGamma r
option greenGamma g
option blueGamma b
option grayGamma gr
option red_gain r
option red_offset ro
option green_gain g
option green_offset go
option blue_gain b
option blue_offset bo
See the plustek.conf file for examples.
Note:
You have to make sure, that the USB subsystem is loaded correctly and you have
access to the device-node. For more details see sane-usb(5) manpage.
You might use sane-find-scanner(1) to check that you have access to
your device.
Note:
If there's no configuration file, the backend defaults to device
auto
FILES¶
- /etc/sane.d/plustek.conf
- The backend configuration file
- /usr/lib64/sane/libsane-plustek.a
- The static library implementing this backend.
- /usr/lib64/sane/libsane-plustek.so
- The shared library implementing this backend (present on systems that support dynamic loading).
ENVIRONMENT¶
- SANE_CONFIG_DIR
- This environment variable specifies the list of directories that may contain the configuration file. On *NIX systems, the directories are separated by a colon (`:'), under OS/2, they are separated by a semi-colon (`;'). If this variable is not set, the configuration file is searched in two default directories: first, the current working directory (".") and then in /etc/sane.d. If the value of the environment variable ends with the directory separator character, then the default directories are searched after the explicitly specified directories. For example, setting SANE_CONFIG_DIR to "/tmp/config:" would result in directories tmp/config, ., and /etc/sane.d being searched (in this order).
- SANE_DEBUG_PLUSTEK
- If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend. Higher debug levels
increase the verbosity of the output.
Example: export SANE_DEBUG_PLUSTEK=10
SEE ALSO¶
sane(7), sane-usb(5), sane-u12(5),
sane-gt68xx(5), sane-mustek_pp(5),
sane-find-scanner(1), scanimage(1)
/usr/share/doc/packages/sane-backends/plustek/Plustek-USB.changes
CONTACT AND BUG-REPORTS¶
Please send any information and bug-reports to:
SANE Mailing List
Additional info and hints can be obtained from our mailing-List archive at: http://www.sane-project.org/mailing-lists.html.
To obtain debug messages from the backend, please set the environment-variable SANE_DEBUG_PLUSTEK before calling your favorite SANE frontend (e.g. scanimage(1)):
export SANE_DEBUG_PLUSTEK=20 ; scanimage
The value controls the verbosity of the output. Please note that values greater than 24 force the backend to output raw data files which could be rather large. The suffix of these files is ".raw". For problem reports it should be enough the set the verbosity to 13.
KNOWN BUGS & RESTRICTIONS¶
* The driver does not support these manic scalings up to 16 times the physical resolution. The only scaling is done on resolutions between the physical resolution of the CCD-/CIS-sensor and the stepper motor i.e. you have a 600x1200 dpi scanner and you are scanning using 800dpi, so scaling is necessary, because the sensor only delivers 600dpi but the motor is capable to perform 1200dpi steps.
* Plusteks' model policy is somewhat inconsistent. They sell technically different devices under the same product name. Therefore it is possible that some devices like the UT12 or U12 won't work - please check the model list above and compare the product-id to the one your device has.
* Negative/Slide scanning quality is poor.
03 Nov 2017 |