NVME-WDC-VS-TELEM(1) | NVMe Manual | NVME-WDC-VS-TELEM(1) |
NAME¶
nvme-wdc-vs-telemetry-controller-option - Disable/Enable the controller initiated option of the telemetry log page.
SYNOPSIS¶
nvme wdc vs-telemetry-controller-option <device>
[--disable, -d] [--enable, -e] [--status, -s]
DESCRIPTION¶
For the NVMe device given, sends the WDC Vendor Specific set feature command to disable, enable or get current status the controller initiated option of the telemetry log page.
The <device> parameter is mandatory NVMe character device (ex: /dev/nvme0).
This will only work on WDC devices supporting this feature. Results for any other device are undefined.
OPTIONS¶
-d, --disable
Disables the controller initiated option of the telemetry
log page.
-e, --enable
Enables the controller initiated option of the telemetry
log page.
-s, --status
Returns the current status (enabled or disabled) of the
controller initiated option of the telemetry log page.
EXAMPLES¶
•Disables the controller initiated option of the
telemetry log page:
# nvme wdc vs-telemetry-controller-option /dev/nvme0 --disable # nvme wdc vs-telemetry-controller-option /dev/nvme0 -d
•Enables the controller initiated option of the
telemetry log page:
# nvme wdc vs-telemetry-controller-option /dev/nvme0 --enable # nvme wdc vs-telemetry-controller-option /dev/nvme0 -e
•Gets the current status (enabled or disabled) of
the controller initiated option of the telemetry log page:
# nvme wdc vs-telemetry-controller-option /dev/nvme0 --status # nvme wdc vs-telemetry-controller-option /dev/nvme0 -s
NVME¶
Part of the nvme-user suite.
10/31/2024 | NVMe |