Scroll to navigation

NVME-VERIFY(1) NVMe Manual NVME-VERIFY(1)

NAME

nvme-verify - Send an NVMe Verify command, return results

SYNOPSIS

nvme [<global-options>] verify <device>

[--namespace-id=<nsid> | -n <nsid>]
[--start-block=<slba> | -s <slba>]
[--block-count=<nlb> | -c <nlb>] [--limited-retry | -l]
[--force-unit-access | -f]
[--prinfo=<prinfo> | -p <prinfo>]
[--ref-tag=<reftag> | -r <reftag>]
[--app-tag-mask=<appmask> | -m <appmask>]
[--app-tag=<apptag> | -a <apptag>]
[--storage-tag<storage-tag> | -S <storage-tag>]
[--storage-tag-check | -C]

DESCRIPTION

The Verify command verifies the integrity of the stored information by reading data and metadata.

OPTIONS

-n <nsid>, --namespace-id=<nsid>

Namespace ID use in the command.

-s <slba>, --start-block=<slba>

Start block address.

-c <nlb>, --block-count=<nlb>

Number of logical blocks to Verify.

-l, --limited-retry

Sets the limited retry flag.

-f, --force-unit-access

Set the force-unit access flag.

-p <prinfo>, --prinfo=<prinfo>

Protection Information field definition.
Bit Description
3 PRACT: Protection Information Action. When set to 1, PI is stripped/inserted on read/write when the block format’s metadata size is 8. When set to 0, metadata is passes.
2:0 PRCHK: Protection Information Check:
2 Set to 1 enables checking the guard tag
1 Set to 1 enables checking the application tag
0 Set to 1 enables checking the reference tag

-r <reftag>, --ref-tag=<reftag>

Optional reftag when used with protection information.

-m <appmask>, --app-tag-mask=<appmask>

Optional application tag mask when used with protection information.

-a <apptag>, --app-tag=<apptag>

Optional application tag when used with protection information.

-S <storage-tag>, --storage-tag=<storage-tag>

Variable Sized Expected Logical Block Storage Tag(ELBST).

-C, --storage-tag-check

This flag enables Storage Tag field checking as part of Verify operation.

GLOBAL OPTIONS

The following options are defined at the top-level nvme command and are available to this subcommand:

--dry-run

Print the command that would be executed, but do not actually execute it.

--no-ioctl-probing

Disable probing for 64-bit IOCTL support.

--no-retries

Disable retry logic on transient errors.

-o <fmt>, --output-format=<fmt>

Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.

--output-format-version=<version>

Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names.

--timeout=<ms>

Set the timeout for the command in milliseconds.

-v, --verbose

Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.

EXAMPLES

No examples yet.

NVME

Part of the nvme-user suite

07/31/2026 NVMe