table of contents
CPCLEAN("1") | HUGIN | CPCLEAN("1") |
NAME¶
cpclean - Remove wrong control points by statistical methods
SYNOPSIS¶
cpclean [options] input.pto
DESCRIPTION¶
cpclean uses statistical methods to remove wrong control points.
Step 1 optimises all images pairs, calculates for each pair mean and standard deviation and removes all control points with error bigger than mean+n*sigma.
Step 2 optimises the whole panorama, calculates mean and standard deviation for all control points and removes all control points with error bigger than mean+n*sigma.
OPTIONS¶
- --output|-o output.pto
- Output Hugin PTO file. Default: '<filename>_clean.pto'.
- --max-distance|-n num
- distance factor for checking (default: 2) (cps with an error > mean + this factor*sigma will be removed)
- --pairwise-checking|-p
- do only image pair cp checking (skip step 2)
- --whole-pano-checking|-w
- do only whole panorama checking (skip step 1)
- --dont-optimize|-s
- skip optimisation step when checking the whole panorama
- --check-line-cp|-l
- also include line control points for calculation and filtering in step 2
- --verbose|-v
- verbose output during optimisation
- --help|-h
- shows help
AUTHORS¶
Thomas Modes
2024-11-22 | "Version: 2024.0.1" |